TB Series | Temperature Control Steam Trap

Steam Traps TB Series | Temperature Control Steam Trap TBU4-SR

Steam Traps TB Series | Temperature Control Steam Trap

TBU4-SR

  • SCCV System
  • Stainless Steel
  • Supports condensate recovery
  • Horizontal installation
  • Vertical installation
  • Bypass function
  • Automatic air venting

    Steam Traps TB Series | Temperature Control Steam Trap TBU4-SR

    Features/Applications

    Features

    • Takes only 1/10th of the previous time required to remove scale

      Disassembly before cleaning is no longer needed. Remove scale instantly by simply turning a handle with no need to stop the flow of steam. The time required is approximately 3 minutes per trap.

    • Reduces scale buildup

      Complete redesign of all internal unit components.
      ・33% increase in bimetal valve stroke volume
      ・Spring opening force 2.2 times stronger
      ・Enlarged valve seat flow channel and space
       *Compared with previous Miyawaki products

    • Pre-emptive action before closing performance deteriorates

      This product enables efficient regular scale removal work. Poor closing performance caused by scale can be prevented through regular scale removal.

    • Superb durability

      SCCV (Self Closing and Centering Valve) System / This is an original mechanism developed by Miyawaki to increase valve durability.
      It has the effect of increasing durability by achieving soft closing.

    Remove scale by simply turning a handle!
    This temperature control trap has a mechanism that allows you to remove scale that has built up in the flow channel (of the valve hole) and discharge it by simply turning a handle at the bottom.

     
    TBU4_remove_image.png
     

    Typical applications

    Suitable for steam tracing lines in plants.

    Dimensions/Weight

    Dimensions/Weight

    TBU4-SR_Rc.png
     
    Size Dimensions (mm) Dimensions (in) Weight
    L H1 H2 W L H1 H2 W (kg) (lb)
    1/4” 65 65 58 46 2.6 2.6 2.3 1.8 0,62 1.37
    3/8”

    Specifications

    Model Connection

    Max. operating

    pressure

    Max. operating

    differential pressure

    Max. operating

    temperature

    Adjustable range

    Standard set

    temperature

    Body

    material

    Type Size

    PMO

    (MPa)

    PMO

    (psig)

    (MPa) (psig)

    TMO

    (℃)

    TMO

    (℉)

    (℃) (℉) (℃) (℉)
    TBU4-6-SR

    Screwed

    Rc,NPT

    1/4”

    0,6*

    87* 0,6 87 220 428 50 - 130 122 - 266

    70

    (at 0,5MPa)

    158
    (at 72.5psig)

    Stainless

    steel

    SUS F304/A182 F304

    3/8”

    *Can also be manufactured with a maximum operating pressure of 1,0MPa (145psig).

    *It is possible to change the standard factory set temperature. Please specify the operating pressure and set temperature.

    *Please refer to the installation manual how to adjust the set temperature.

    Discharge Capacity

    TBU4,TBU4B-6.png
     

    ●⊿t is the difference between the temperature of a temperature control trap when the valve is initially opened and condensate temperature.

     The temperature difference (⊿t) upon the initial passage of air is great, and indicates that the flow rate will also increase.

     

    Curve1 shows the trap's maximum capacity when discharaging cold condensate.

    **Curve2 shows the trap's maximum capacity when discharaging hot condensate at a temperature of 10°C (18°F) below the adjusted temperature of the trap.

    Procedure for scale removal

    TBU4-SR_howto_2.png

    Download

    * Membership registration is required to download the documents.

    Features

    • Takes only 1/10th of the previous time required to remove scale

      Disassembly before cleaning is no longer needed. Remove scale instantly by simply turning a handle with no need to stop the flow of steam. The time required is approximately 3 minutes per trap.

    • Reduces scale buildup

      Complete redesign of all internal unit components.
      ・33% increase in bimetal valve stroke volume
      ・Spring opening force 2.2 times stronger
      ・Enlarged valve seat flow channel and space
       *Compared with previous Miyawaki products

    • Pre-emptive action before closing performance deteriorates

      This product enables efficient regular scale removal work. Poor closing performance caused by scale can be prevented through regular scale removal.

    • Superb durability

      SCCV (Self Closing and Centering Valve) System / This is an original mechanism developed by Miyawaki to increase valve durability.
      It has the effect of increasing durability by achieving soft closing.

    Remove scale by simply turning a handle!
    This temperature control trap has a mechanism that allows you to remove scale that has built up in the flow channel (of the valve hole) and discharge it by simply turning a handle at the bottom.

     
    TBU4_remove_image.png
     

    Typical applications

    Suitable for steam tracing lines in plants.

    Dimensions/Weight

    TBU4-SR_Rc.png
     
    Size Dimensions (mm) Dimensions (in) Weight
    L H1 H2 W L H1 H2 W (kg) (lb)
    1/4” 65 65 58 46 2.6 2.6 2.3 1.8 0,62 1.37
    3/8”
    Model Connection

    Max. operating

    pressure

    Max. operating

    differential pressure

    Max. operating

    temperature

    Adjustable range

    Standard set

    temperature

    Body

    material

    Type Size

    PMO

    (MPa)

    PMO

    (psig)

    (MPa) (psig)

    TMO

    (℃)

    TMO

    (℉)

    (℃) (℉) (℃) (℉)
    TBU4-6-SR

    Screwed

    Rc,NPT

    1/4”

    0,6*

    87* 0,6 87 220 428 50 - 130 122 - 266

    70

    (at 0,5MPa)

    158
    (at 72.5psig)

    Stainless

    steel

    SUS F304/A182 F304

    3/8”

    *Can also be manufactured with a maximum operating pressure of 1,0MPa (145psig).

    *It is possible to change the standard factory set temperature. Please specify the operating pressure and set temperature.

    *Please refer to the installation manual how to adjust the set temperature.

    TBU4,TBU4B-6.png
     

    ●⊿t is the difference between the temperature of a temperature control trap when the valve is initially opened and condensate temperature.

     The temperature difference (⊿t) upon the initial passage of air is great, and indicates that the flow rate will also increase.

     

    Curve1 shows the trap's maximum capacity when discharaging cold condensate.

    **Curve2 shows the trap's maximum capacity when discharaging hot condensate at a temperature of 10°C (18°F) below the adjusted temperature of the trap.

    TBU4-SR_howto_2.png

    * Membership registration is required to download the documents.

    Contact