TB Series | Temperature Control Steam Trap
Steam Traps TB Series | Temperature Control Steam Trap
TB1N
For copper pipe traces
Features/Applications
Features
This product can be installed for use either horizontally or vertically.
Compact design
Can be installed in small spaces.
Uses a highly sensitive disc bimetal
Precise operation in response to even slight temperature changes. The trap’s light weight also means it only places a slight load on the copper or other pipe to which it is connected.
Stable tracing
MIYAWAKI’s own original valve mechanism suppresses fluctuations in trace temperature and reduces temperature unevenness.
Simple maintenance
Maintenance is simple thanks to bimetals being grouped into units.
Typical applications
Suitable for steam tracing and instruments in the fields of oil, petroleum chemistry, electricity, iron manufacturing, and other such fields.
Dimensions/Weight
Dimensions/Weight
Size | Dimensions (mm) | Dimensions (in) | Weight | |||
L | W | L | W | (kg) | (lb) | |
1/4” | 70 | 38 | 2.8 | 1.5 | 0,35 | 0.8 |
3/8” |
Specifications
Model | Connection |
Max. operating pressure |
Max. operating differential pressure |
Max. operating temperature |
Adjustable range |
Standard set temperature |
Body material |
||||||
Type | Size |
PMO (MPa) |
PMO (psig) |
(MPa) | (psig) |
TMO (℃) |
TMO (℉) |
(℃) | (℉) | (℃) | (℉) | ||
TB1N |
Screwed Rc,NPT |
1/4” | 1,6 | 232 | 1,6 | 232 | 350 | 662 | 50 - 90 | 122 - 194 | 70 (at 0,5MPa) |
158 (at 73psig) |
Carbon steel S25C |
3/8” |
Discharge Capacity
●⊿t is the difference between the temperature of a temperature control trap when the valve is initially opened and condensate temperature.
The temperature difference (⊿t) upon the initial passage of air is great, and indicates that the flow rate will also increase.
* Curve1 shows the trap's maximum capacity when discharaging cold condensate.
**Curve2 shows the trap's maximum capacity when discharaging hot condensate at a temperature of 5°C (9°F) below the adjusted temperature of the trap.
Installation Examples
Download
* Membership registration is required to download the documents.
Features
This product can be installed for use either horizontally or vertically.
Compact design
Can be installed in small spaces.
Uses a highly sensitive disc bimetal
Precise operation in response to even slight temperature changes. The trap’s light weight also means it only places a slight load on the copper or other pipe to which it is connected.
Stable tracing
MIYAWAKI’s own original valve mechanism suppresses fluctuations in trace temperature and reduces temperature unevenness.
Simple maintenance
Maintenance is simple thanks to bimetals being grouped into units.
Typical applications
Suitable for steam tracing and instruments in the fields of oil, petroleum chemistry, electricity, iron manufacturing, and other such fields.
Dimensions/Weight
Size | Dimensions (mm) | Dimensions (in) | Weight | |||
L | W | L | W | (kg) | (lb) | |
1/4” | 70 | 38 | 2.8 | 1.5 | 0,35 | 0.8 |
3/8” |
Model | Connection |
Max. operating pressure |
Max. operating differential pressure |
Max. operating temperature |
Adjustable range |
Standard set temperature |
Body material |
||||||
Type | Size |
PMO (MPa) |
PMO (psig) |
(MPa) | (psig) |
TMO (℃) |
TMO (℉) |
(℃) | (℉) | (℃) | (℉) | ||
TB1N |
Screwed Rc,NPT |
1/4” | 1,6 | 232 | 1,6 | 232 | 350 | 662 | 50 - 90 | 122 - 194 | 70 (at 0,5MPa) |
158 (at 73psig) |
Carbon steel S25C |
3/8” |
●⊿t is the difference between the temperature of a temperature control trap when the valve is initially opened and condensate temperature.
The temperature difference (⊿t) upon the initial passage of air is great, and indicates that the flow rate will also increase.
* Curve1 shows the trap's maximum capacity when discharaging cold condensate.
**Curve2 shows the trap's maximum capacity when discharaging hot condensate at a temperature of 5°C (9°F) below the adjusted temperature of the trap.
* Membership registration is required to download the documents.