TB Series | Temperature Control Steam Trap

Steam Traps TB Series | Temperature Control Steam Trap TB1N

Steam Traps TB Series | Temperature Control Steam Trap

TB1N

  • SCCV System
  • Stainless Steel
  • Supports condensate recovery
  • Horizontal installation
  • Vertical installation
  • Bypass function
  • Automatic air venting

    For copper pipe traces

    Steam Traps TB Series | Temperature Control Steam Trap TB1N

    Features/Applications

    Features

    • This product can be installed for use either horizontally or vertically.

       

    • Compact design

      Can be installed in small spaces.

    • Uses a highly sensitive disc bimetal

      Precise operation in response to even slight temperature changes. The trap’s light weight also means it only places a slight load on the copper or other pipe to which it is connected.

    • Stable tracing

      MIYAWAKI’s own original valve mechanism suppresses fluctuations in trace temperature and reduces temperature unevenness.

    • Simple maintenance

      Maintenance is simple thanks to bimetals being grouped into units.

    Typical applications

    Suitable for steam tracing and instruments in the fields of oil, petroleum chemistry, electricity, iron manufacturing, and other such fields.

    Dimensions/Weight

    Dimensions/Weight

    TB1N-1.png

     

    Size Dimensions (mm) Dimensions (in) Weight
    L W L W (kg) (lb)
    1/4” 70 38 2.8 1.5 0,35 0.8
    3/8”

    Specifications

    Model Connection

    Max. operating

    pressure

    Max. operating

    differential pressure

    Max. operating

    temperature

    Adjustable range

    Standard set

    temperature

    Body

    material

    Type Size

    PMO

    (MPa)

    PMO

    (psig)

    (MPa) (psig)

    TMO

    (℃)

    TMO

    (℉)

    (℃) (℉) (℃) (℉)
    TB1N

    Screwed

    Rc,NPT

    1/4” 1,6 232 1,6 232 350 662 50 - 90 122 - 194 70
    (at 0,5MPa)
    158
    (at 73psig)

    Carbon

    steel

    S25C

    3/8”
    *It is possible to change the standard factory set temperature. Please specify the operating pressure and set temperature.

    Discharge Capacity

    TB1N.png

    ●⊿t is the difference between the temperature of a temperature control trap when the valve is initially opened and condensate temperature.

     The temperature difference (⊿t) upon the initial passage of air is great, and indicates that the flow rate will also increase.

     

    Curve1 shows the trap's maximum capacity when discharaging cold condensate.

    **Curve2 shows the trap's maximum capacity when discharaging hot condensate at a temperature of 5°C (9°F) below the adjusted temperature of the trap.

    Installation Examples

    TB1N_haikan.png

    Download

    * Membership registration is required to download the documents.

    Features

    • This product can be installed for use either horizontally or vertically.

       

    • Compact design

      Can be installed in small spaces.

    • Uses a highly sensitive disc bimetal

      Precise operation in response to even slight temperature changes. The trap’s light weight also means it only places a slight load on the copper or other pipe to which it is connected.

    • Stable tracing

      MIYAWAKI’s own original valve mechanism suppresses fluctuations in trace temperature and reduces temperature unevenness.

    • Simple maintenance

      Maintenance is simple thanks to bimetals being grouped into units.

    Typical applications

    Suitable for steam tracing and instruments in the fields of oil, petroleum chemistry, electricity, iron manufacturing, and other such fields.

    Dimensions/Weight

    TB1N-1.png

     

    Size Dimensions (mm) Dimensions (in) Weight
    L W L W (kg) (lb)
    1/4” 70 38 2.8 1.5 0,35 0.8
    3/8”
    Model Connection

    Max. operating

    pressure

    Max. operating

    differential pressure

    Max. operating

    temperature

    Adjustable range

    Standard set

    temperature

    Body

    material

    Type Size

    PMO

    (MPa)

    PMO

    (psig)

    (MPa) (psig)

    TMO

    (℃)

    TMO

    (℉)

    (℃) (℉) (℃) (℉)
    TB1N

    Screwed

    Rc,NPT

    1/4” 1,6 232 1,6 232 350 662 50 - 90 122 - 194 70
    (at 0,5MPa)
    158
    (at 73psig)

    Carbon

    steel

    S25C

    3/8”
    *It is possible to change the standard factory set temperature. Please specify the operating pressure and set temperature.
    TB1N.png

    ●⊿t is the difference between the temperature of a temperature control trap when the valve is initially opened and condensate temperature.

     The temperature difference (⊿t) upon the initial passage of air is great, and indicates that the flow rate will also increase.

     

    Curve1 shows the trap's maximum capacity when discharaging cold condensate.

    **Curve2 shows the trap's maximum capacity when discharaging hot condensate at a temperature of 5°C (9°F) below the adjusted temperature of the trap.

    TB1N_haikan.png

    * Membership registration is required to download the documents.

    Contact