G Series | Ball Float Steam Traps

Steam Traps G Series | Ball Float Steam Traps GH60D

Steam Traps G Series | Ball Float Steam Traps

GH60D

  • SCCV System
  • Stainless Steel
  • Supports condensate recovery
  • Horizontal installation
  • Vertical installation
  • Bypass function
  • Automatic air venting
    • Option
      - ASTM material available

    Stainless steel OK

    Steam Traps G Series | Ball Float Steam Traps GH60D

    Features/Applications

    Features

    • Quick startup

      Automatically discharges initial air and cold condensate. The diaphragm air vent follows the saturation temperature and prevents air and steam locking.

    • Suitable for medium to high capacity steam processes

      Adjust the degree of valve opening according to volume of condensate generated to provide maximized heat exchange capacity.

    • Condensate recovery

      With its high degree of back pressure tolerance, this model supports condensate recovery.

    • Easy maintenance

      For quick and easy maintenance, this model can be repaired directly in line.

    • High discharge capacity

      A double ported balance valve provides a large discharge capacity in comparison with single valve models.

    hukuza.png
     

    Typical applications

    Suitable for use in industrial plant systems, foodstuff devices, and dyeing/cleaning devices.

    Dimensions/Weight

    Dimensions/Weight

    Flanged

    GH60_FF.png

     

    Size Dimensions (mm) Dimensions (in) Weight
    L H1 H2 W1 W2 L H1 H2 W1 W2 (kg) (lb)
    2”

    320

    155 250 90 410 12.6 6.1 9.8 3.5 16.1

    75,0

    165.4
    2 1/2”

    *Available flange standards: ASME/JPI 150lb, 300lb, DIN PN40, JIS 10K, 16K, 20K
    *Customized face-to-face dimensions on request.
    *Please contact MIYAWAKI for further information.

    Specifications

    Model Connection

    Max. operating

    pressure

    Max. operating differential

    pressure

    Max. operating

    temperature

    Air vent

    type

    Body

    material

    Type Size

    PMO

    (MPa)

    PMO

    (psig)

    ⊿PMX

    (MPa)

    ⊿PMX

    (psig)

    TMO

    (℃)

    TMO

    (℉)

    GH60D-2F

    Flanged

    FF,RF*

    2” 0,2 29 0,2 29 220 428 Diaphragm

    Cast steel

    SCPH2/WCB

    2 1/2”
    GH60D-6F 2” 0,6 87 0,6 87
    2 1/2”
    GH60D-10F 2” 1,0 145 1,0 145
    2 1/2”
    GH60D-21F 2” 2,1 305 2,1 305
    2 1/2”

    *Available flange standards: ASME/JPI 150lb, 300lb, DIN PN40, JIS 10K, 16K, 20K

    ●Maximum allowable pressure (PMA): 4,0MPa (580psig)
    ●Maximum allowable temperature (TMA): 400℃ (752℉)
    ●Maximum operating back pressure (PMOB): 90% of inlet-side pressure

    *ASTM material (WCB) on request.

    ●This product uses a double ported balance valve system so if the actual condensate volume is significantly lower than the product’s discharge capacity, there may be a steam leak.

    Discharge Capacity

    GH60D.png

    Download

    * Membership registration is required to download the documents.

    Features

    • Quick startup

      Automatically discharges initial air and cold condensate. The diaphragm air vent follows the saturation temperature and prevents air and steam locking.

    • Suitable for medium to high capacity steam processes

      Adjust the degree of valve opening according to volume of condensate generated to provide maximized heat exchange capacity.

    • Condensate recovery

      With its high degree of back pressure tolerance, this model supports condensate recovery.

    • Easy maintenance

      For quick and easy maintenance, this model can be repaired directly in line.

    • High discharge capacity

      A double ported balance valve provides a large discharge capacity in comparison with single valve models.

    hukuza.png
     

    Typical applications

    Suitable for use in industrial plant systems, foodstuff devices, and dyeing/cleaning devices.

    Dimensions/Weight

    Flanged

    GH60_FF.png

     

    Size Dimensions (mm) Dimensions (in) Weight
    L H1 H2 W1 W2 L H1 H2 W1 W2 (kg) (lb)
    2”

    320

    155 250 90 410 12.6 6.1 9.8 3.5 16.1

    75,0

    165.4
    2 1/2”

    *Available flange standards: ASME/JPI 150lb, 300lb, DIN PN40, JIS 10K, 16K, 20K
    *Customized face-to-face dimensions on request.
    *Please contact MIYAWAKI for further information.

    Model Connection

    Max. operating

    pressure

    Max. operating differential

    pressure

    Max. operating

    temperature

    Air vent

    type

    Body

    material

    Type Size

    PMO

    (MPa)

    PMO

    (psig)

    ⊿PMX

    (MPa)

    ⊿PMX

    (psig)

    TMO

    (℃)

    TMO

    (℉)

    GH60D-2F

    Flanged

    FF,RF*

    2” 0,2 29 0,2 29 220 428 Diaphragm

    Cast steel

    SCPH2/WCB

    2 1/2”
    GH60D-6F 2” 0,6 87 0,6 87
    2 1/2”
    GH60D-10F 2” 1,0 145 1,0 145
    2 1/2”
    GH60D-21F 2” 2,1 305 2,1 305
    2 1/2”

    *Available flange standards: ASME/JPI 150lb, 300lb, DIN PN40, JIS 10K, 16K, 20K

    ●Maximum allowable pressure (PMA): 4,0MPa (580psig)
    ●Maximum allowable temperature (TMA): 400℃ (752℉)
    ●Maximum operating back pressure (PMOB): 90% of inlet-side pressure

    *ASTM material (WCB) on request.

    ●This product uses a double ported balance valve system so if the actual condensate volume is significantly lower than the product’s discharge capacity, there may be a steam leak.

    GH60D.png

    * Membership registration is required to download the documents.

    Contact