G Series | Ball Float Steam Traps
Steam Traps G Series | Ball Float Steam Traps
GH3N
Stainless steel OK
Features/Applications
Features
Quick startup
Automatically discharges initial air and cold condensate.
Condensate recovery
With its high degree of back pressure tolerance, this model supports condensate recovery.
High discharge capacity
A double ported balance valve provides a large discharge capacity in comparison with single valve models.
Typical applications
Suitable for uses including large-scale heat exchangers in various industries, and in things such as industrial plants, foodstuff devices, dyeing/cleaning devices, and air conditioning devices.
Dimensions/Weight
Dimensions/Weight
Flanged
Size | Dimensions (mm) | Dimensions (in) | Weight | |||||||
L | H1 | H2 | W | L | H1 | H2 | W | (kg) | (lb) | |
1 1/2” | 275 | 139 | 106 | 212 | 10.8 | 5.5 | 4.2 | 8.4 | 30,0 | 66.2 |
*Available flange standards: ASME/JPI 300lb
With connection flange
Size |
Flange standards |
L dimensions (mm) |
H1 | H2 | W |
L dimensions (in) |
H1 | H2 | W |
Weight |
|
(kg) | (lb) | ||||||||||
1” | JIS 10K,16K,20K |
447 | 139 | 106 | 212 | 17.6 | 5.5 | 4.2 | 8.4 | 38,0 | 83.8 |
ASME/JPI 150lb,300lb |
457 | 18.0 | |||||||||
DIN PN40 (DN25) | |||||||||||
1 1/4” | JIS 10K,16K,20K |
447 | 17.6 | 39,0 | 86 | ||||||
ASME/JPI 150lb,300lb |
457 | 18.0 | |||||||||
DIN PN40 (DN32) | |||||||||||
1 1/2” | JIS 10K,16K,20K |
477 | 18.8 | 40,0 | 88.2 | ||||||
ASME/JPI |
|||||||||||
DIN PN40 (DN40) | |||||||||||
2” |
JIS |
477 | 18.8 | 41,0 | 90.4 | ||||||
ASME/JPI 150lb,300lb |
487 | 19.2 | |||||||||
DIN PN40 (DN50) | |||||||||||
2 1/2” |
JIS |
507 | 20.0 | 46,0 | 101.4 | ||||||
ASME/JPI 150lb,300lb |
517 | 20.4 | |||||||||
DIN PN40 (DN60) | |||||||||||
3" | JIS 10K,16K,20K |
507 | 20.0 | 50,0 | 110.3 | ||||||
ASME/JPI 150lb,300lb |
517 | 20.4 | |||||||||
DIN PN40 (DN80) |
*Available flange standards: ASME/JPI 150lb, 300lb, DIN PN40, JIS 10K, 16K, 20K
*Customized face-to-face dimensions on request.
*Please contact MIYAWAKI for further information.
Specifications
Model | Connection |
Max. operating pressure |
Max. operating differential pressure |
Max. operating temperature |
Body material |
||||
Type | Size | PMO (MPa) | PMO (psig) | ⊿PMX (MPa) | ⊿PMX (psig) | TMO (℃) | TMO (℉) | ||
GH3N-10 |
Flanged RF*1 |
1 1/2” | 1,0 | 145 | 1,0 | 145 | 400 | 752 |
Cast steel SCPH2/WCB |
GH3N-16 | 1,6 | 230 | 1,6 | 230 | |||||
GH3N-21 | 2,1 | 305 | 2,1 | 305 | |||||
GH3N-10R |
Flanged FF,RF*2 |
1 1/2”・2”・2 1/2”・3" | 1,0 | 145 | 1,0 | 145 | |||
GH3N-16R | 1”・1 1/4”・1 1/2”・2”・2 1/2”・3" | 1,6 | 230 | 1,6 | 230 | ||||
GH3N-21R | 1”・1 1/4”・1 1/2”・2”・2 1/2”・3" | 2,1 | 305 | 2,1 | 305 |
*1 Available flange standards: ASME/JPI 300lb
*2 Available flange standards: ASME/JPI 150lb, 300lb, DIN PN40, JIS 10K, 16K, 20K
●This product uses a double ported balance valve system so if the actual condensate volume is significantly lower than the product’s discharge capacity, there may be a steam leak.
Discharge Capacity
●The discharge line chart shows the discharge rate for condensate with a temperature 6℃ (43℉) lower than the saturation temperature.
Download
* Membership registration is required to download the documents.
Features
Quick startup
Automatically discharges initial air and cold condensate.
Condensate recovery
With its high degree of back pressure tolerance, this model supports condensate recovery.
High discharge capacity
A double ported balance valve provides a large discharge capacity in comparison with single valve models.
Typical applications
Suitable for uses including large-scale heat exchangers in various industries, and in things such as industrial plants, foodstuff devices, dyeing/cleaning devices, and air conditioning devices.
Dimensions/Weight
Flanged
Size | Dimensions (mm) | Dimensions (in) | Weight | |||||||
L | H1 | H2 | W | L | H1 | H2 | W | (kg) | (lb) | |
1 1/2” | 275 | 139 | 106 | 212 | 10.8 | 5.5 | 4.2 | 8.4 | 30,0 | 66.2 |
*Available flange standards: ASME/JPI 300lb
With connection flange
Size |
Flange standards |
L dimensions (mm) |
H1 | H2 | W |
L dimensions (in) |
H1 | H2 | W |
Weight |
|
(kg) | (lb) | ||||||||||
1” | JIS 10K,16K,20K |
447 | 139 | 106 | 212 | 17.6 | 5.5 | 4.2 | 8.4 | 38,0 | 83.8 |
ASME/JPI 150lb,300lb |
457 | 18.0 | |||||||||
DIN PN40 (DN25) | |||||||||||
1 1/4” | JIS 10K,16K,20K |
447 | 17.6 | 39,0 | 86 | ||||||
ASME/JPI 150lb,300lb |
457 | 18.0 | |||||||||
DIN PN40 (DN32) | |||||||||||
1 1/2” | JIS 10K,16K,20K |
477 | 18.8 | 40,0 | 88.2 | ||||||
ASME/JPI |
|||||||||||
DIN PN40 (DN40) | |||||||||||
2” |
JIS |
477 | 18.8 | 41,0 | 90.4 | ||||||
ASME/JPI 150lb,300lb |
487 | 19.2 | |||||||||
DIN PN40 (DN50) | |||||||||||
2 1/2” |
JIS |
507 | 20.0 | 46,0 | 101.4 | ||||||
ASME/JPI 150lb,300lb |
517 | 20.4 | |||||||||
DIN PN40 (DN60) | |||||||||||
3" | JIS 10K,16K,20K |
507 | 20.0 | 50,0 | 110.3 | ||||||
ASME/JPI 150lb,300lb |
517 | 20.4 | |||||||||
DIN PN40 (DN80) |
*Available flange standards: ASME/JPI 150lb, 300lb, DIN PN40, JIS 10K, 16K, 20K
*Customized face-to-face dimensions on request.
*Please contact MIYAWAKI for further information.
Model | Connection |
Max. operating pressure |
Max. operating differential pressure |
Max. operating temperature |
Body material |
||||
Type | Size | PMO (MPa) | PMO (psig) | ⊿PMX (MPa) | ⊿PMX (psig) | TMO (℃) | TMO (℉) | ||
GH3N-10 |
Flanged RF*1 |
1 1/2” | 1,0 | 145 | 1,0 | 145 | 400 | 752 |
Cast steel SCPH2/WCB |
GH3N-16 | 1,6 | 230 | 1,6 | 230 | |||||
GH3N-21 | 2,1 | 305 | 2,1 | 305 | |||||
GH3N-10R |
Flanged FF,RF*2 |
1 1/2”・2”・2 1/2”・3" | 1,0 | 145 | 1,0 | 145 | |||
GH3N-16R | 1”・1 1/4”・1 1/2”・2”・2 1/2”・3" | 1,6 | 230 | 1,6 | 230 | ||||
GH3N-21R | 1”・1 1/4”・1 1/2”・2”・2 1/2”・3" | 2,1 | 305 | 2,1 | 305 |
*1 Available flange standards: ASME/JPI 300lb
*2 Available flange standards: ASME/JPI 150lb, 300lb, DIN PN40, JIS 10K, 16K, 20K
●This product uses a double ported balance valve system so if the actual condensate volume is significantly lower than the product’s discharge capacity, there may be a steam leak.
●The discharge line chart shows the discharge rate for condensate with a temperature 6℃ (43℉) lower than the saturation temperature.
* Membership registration is required to download the documents.