Direct Acting for steam

Pressure Reducing Valves Direct Acting for steam REC20

Pressure Reducing Valves Direct Acting for steam

REC20

  • SCCV System
  • Stainless Steel
  • Supports condensate recovery
  • Horizontal installation
  • Vertical installation
  • Bypass function
  • Automatic air venting

    Pressure Reducing Valves Direct Acting for steam REC20

    Features/Applications

    Features

    • Self-acting pressure reducing valve for steam

      This valve reduces the steam supply pressure to a defined outlet pressure and keeps it steady, even under downstream fluctuations . The valves needs no seperate energy source.

    • Operating features of direct acting pressure reducing valves

      Pressure changes on the downstream side are detected in the detection chamber, and the degree of opening of the valve is directly adjusted to keep the pressure on the downstream side at set pressure.

    • Wide range of pressure reduction

      Due to carfefully selected springs an outstanding reduction ratio of 25:1 is achieved.

    • Diaphram free design

      The valve operates with an O-ring sealing and a piston design. Due to this design, no daiphragm and no external sensing line is required.

    • Superb durability

      Highly durable and carefully selected components, a 360° free rotating, conical plug and the lack of a sensitive diaphragm ensure outstanding lifetime of this valve.

    • Options available

      - additional pressure gauges - tailored connections for special applications - softsealing for leakage class VI

    Typical applications

    Perfect for all applications with medium to high steam flow or high reduction. In particuliar power plants, chemical and petrochemical process applications, ships, food and beverage plants, and other similar installations of of compact steam equipment.

    Dimensions/Weight

    Dimensions/Weight

    RE20_Dimension_dwg.png

     

    Size
    (DN)
    Dimensions (mm)

    Kvs

    Value

    Weight

    (kg)

    L H h
    15 130 410 82 1,8 12,0
    20 150 66 3,2 12,0
    25 160

    66

    5,0 13,0
    32 180 81 7,9 16,0
    40 200 83 13,0 18,0
    50 230 586 100 20,0 37,5
    65 290 615 113 34,0 43,0
    80 310 733 140 51,0 58,0
    100 350 762 154 80,0 77,0
    125 400 715 210 130,0 155,0
    150 480 720 235 180,0 190,0
    200 600 950 285 320,0 385,0

     

     

     

    Specifications

    Body Material
     
    Ductile cast iron
    EN-GJS-400-15
    (GGG-40,0.7040)
     
    Body design conditions
      PN16 PN25
    Max. design pressure (MPa)           PMA 1,6 2,5
    Max. design temperature (℃)        TMA 350 350
    Max. operating pressure (MPa)     PMO 1,5 2,2
    Max. operating temperature (℃)  TMO 350 350
    Pressure - Temperature rating
    PN Temperature ℃
    -10・・・+50 100 150 200 250 300 350
    Pressure MPa
    PN16 1,6 1,6 1,6 1,5 1,4 1,3 1,1
    PN25 2,5 2,5 2,4 2,3 2,2 2,0 1,8
    Secondary pressure ranges

    Secondary

    pressure range

    DN15-DN40 DN50 DN65 DN80 DN100 DN125-DN200
    MPa Spring number per size
    0,05-0,1 9 28 27 38 37 On request
    0,1-0,16 8 27 26 37 36
    0,16-0,25 7 26 25 36 35
    0,25-0,4 6 25 24 35 34
    0,4-0,63 5 24 23 34 33
    0,63-1,0 4 23 22 33 32
    1,0-1,6 3 22 21 32 32

    Secondary pressure ranges higher than 1,6 MPa on request.

    A minimum differential pressure of 0,05 Mpa is required

     

     
     
     
     
     
     
     
     
     

    Capacity Chart

    RE20_p14.png

    RE20_p15.png

    RE20_p16.png

    Download

    * Membership registration is required to download the documents.

    Features

    • Self-acting pressure reducing valve for steam

      This valve reduces the steam supply pressure to a defined outlet pressure and keeps it steady, even under downstream fluctuations . The valves needs no seperate energy source.

    • Operating features of direct acting pressure reducing valves

      Pressure changes on the downstream side are detected in the detection chamber, and the degree of opening of the valve is directly adjusted to keep the pressure on the downstream side at set pressure.

    • Wide range of pressure reduction

      Due to carfefully selected springs an outstanding reduction ratio of 25:1 is achieved.

    • Diaphram free design

      The valve operates with an O-ring sealing and a piston design. Due to this design, no daiphragm and no external sensing line is required.

    • Superb durability

      Highly durable and carefully selected components, a 360° free rotating, conical plug and the lack of a sensitive diaphragm ensure outstanding lifetime of this valve.

    • Options available

      - additional pressure gauges - tailored connections for special applications - softsealing for leakage class VI

    Typical applications

    Perfect for all applications with medium to high steam flow or high reduction. In particuliar power plants, chemical and petrochemical process applications, ships, food and beverage plants, and other similar installations of of compact steam equipment.

    Dimensions/Weight

    RE20_Dimension_dwg.png

     

    Size
    (DN)
    Dimensions (mm)

    Kvs

    Value

    Weight

    (kg)

    L H h
    15 130 410 82 1,8 12,0
    20 150 66 3,2 12,0
    25 160

    66

    5,0 13,0
    32 180 81 7,9 16,0
    40 200 83 13,0 18,0
    50 230 586 100 20,0 37,5
    65 290 615 113 34,0 43,0
    80 310 733 140 51,0 58,0
    100 350 762 154 80,0 77,0
    125 400 715 210 130,0 155,0
    150 480 720 235 180,0 190,0
    200 600 950 285 320,0 385,0

     

     

     

    Body Material
     
    Ductile cast iron
    EN-GJS-400-15
    (GGG-40,0.7040)
     
    Body design conditions
      PN16 PN25
    Max. design pressure (MPa)           PMA 1,6 2,5
    Max. design temperature (℃)        TMA 350 350
    Max. operating pressure (MPa)     PMO 1,5 2,2
    Max. operating temperature (℃)  TMO 350 350
    Pressure - Temperature rating
    PN Temperature ℃
    -10・・・+50 100 150 200 250 300 350
    Pressure MPa
    PN16 1,6 1,6 1,6 1,5 1,4 1,3 1,1
    PN25 2,5 2,5 2,4 2,3 2,2 2,0 1,8
    Secondary pressure ranges

    Secondary

    pressure range

    DN15-DN40 DN50 DN65 DN80 DN100 DN125-DN200
    MPa Spring number per size
    0,05-0,1 9 28 27 38 37 On request
    0,1-0,16 8 27 26 37 36
    0,16-0,25 7 26 25 36 35
    0,25-0,4 6 25 24 35 34
    0,4-0,63 5 24 23 34 33
    0,63-1,0 4 23 22 33 32
    1,0-1,6 3 22 21 32 32

    Secondary pressure ranges higher than 1,6 MPa on request.

    A minimum differential pressure of 0,05 Mpa is required

     

     
     
     
     
     
     
     
     
     