Direct Acting for steam

Pressure Reducing Valves Direct Acting for steam RE1

Pressure Reducing Valves Direct Acting for steam

RE1

      Built-in screen

      Pressure Reducing Valves Direct Acting for steam RE1

      Features/Applications

      Features

      • Self acting pressure reducing valve for steam

        Automatic valve that reduces the steam supply pressure to a defined set pressure.
        Pressure fluctuations on upstream side are followed by the downstream side.
        No external energy required

      • Operating features of direct acting pressure reducing valves

        Downstream pressure changes are detected in the detection chamber, and the degree of opening of the valve is directly adjusted to maintain the set pressure.

      • Compact and cost effective design

        Can be installed in tight spaces thanks to its compact design (small/lightweight). Offers reliable operation, energy saving, and productivity improvement.

      • Superb durability

        Control bellows with moren than ... operating cycles offers outstanding durability. Protected by integrated strainer.

      • Easy handling

        Pressure can easily adjusted by the topside handle.

      Typical applications

      Perfect for small to medium steam flows as present in laundries, F&B equipment, sterilizers and similar equipment. 

      Dimensions/Weight

      Dimensions/Weight

      RE1_124_Rc.png

       

      Size Dimensions (mm) Dimensions (in) Weight
      L H1 H2 W L H1 H2 W (kg) (lb)
      1/2” 80 137 46 65 3.2 5.4 1.8 2.6 1,4 3.1
      3/4” 90 3.5 1,6 3.5
      1” 105 144 58 4.1 5.7 2.3 1,9 4.2

      Specifications

      Model Connection

      Max.

      operating

       

      pressure (PMO)

      operating

      pressure range

      Control

      pressure range

      Values

      Max. pressure

      reduction ratio

      Max. operating

      temperature

      (TMO)

      Body

      material

      Type Size (MPa) (psig)

      Primary side

      pressure

      (MPa)

      Primary side

      pressure

      (psig)

      Secondary side

      pressure

      (MPa)

      Secondary side

      pressure

      (psig)

      Cv kvs (℃) (℉)
      RE1

      Screwed

      Rc,NPT

      1/2” 1,6 230 0,2 - 1,6 29 - 230 0,05 - 1,0 7.3 - 145  1,2   1,0   10:1 204 399

      Brass

      C3771

      3/4” 1,9 1,6
      1” 3,2 2,8
      RE1-2 1/2” 1,0 145 0,2 - 1,0 29 - 145 0,02 - 0,2 2.9 - 29 1,9 1,6
      3/4” 1,9 1,6
      1” 2,1   1,8   
      RE1-4 1/2” 1,0 145 0,2 - 1,0 29 - 145 0,05 - 0,4 7.3 - 58 1,2 1,0
      3/4” 1,9 1,6
      1” 3,2 2,8
      ● Recommended accessories: Y strainer / YM1  x1
      ● Offset: RE1: 0.15MPa (21.8psig) or lower, RE1-2: 0.05MPa (7.3psig) or lower, RE1-4: 0,07MPa (10.2psig) or lower
      ● Minimum differential pressure: 20% of the primary side
      ● Lockup pressure: 0,03MPa (4.4psig) or lower

      Capacity Chart (MPa)

      RE1
      RE1_MPa.png

      ● How to use this chart

      1. Find the point at which the upstream pressure and desired downstream pressure horizontal line intersect.

      2. Trace a vertical line from the point where they intersect, and select for the smallest-nominal size where the required steam flow rate met.

      *for downstream pressures from 0,4MPa (58psig) (4kgf/cm2・g) to 0,2MPa (29psig) (2kgf/cm2・g) or lower, use RE1-4 model.

        for downstream pressures from 0,2MPa (29psig) (2kgf/cm2・g) or lower with high flow rate, RE1-2 is recommended.

       
       

      RE1-2
      RE1-2_MPa.png

      RE1-4

      RE1-4_MPa_f.png

       

      Capacity Chart(psig)

      RE1

      RE1_psig.png

      ● How to use this chart

      1. Find the point at which the upstream pressure and desired downstream pressure horizontal line intersect.

      2. Trace a vertical line from the point where they intersect, and select for the smallest-nominal size where the required steam flow rate meet.

      *for downstream pressures from 0,4MPa (58psig) (4kgf/cm2・g) to 0,2MPa (29psig) (2kgf/cm2・g) or lower, use RE1-4 model.

        for downstream pressures from 0,2MPa (29psig) (2kgf/cm2・g) or lower with high flow rate, RE1-2 is recommended.

       


      RE1-2

      RE1-2_psig.png

       

      RE1-4

      RE1-4_psig_f.png

       

      Download

      * Membership registration is required to download the documents.

      Features

      • Self acting pressure reducing valve for steam

        Automatic valve that reduces the steam supply pressure to a defined set pressure.
        Pressure fluctuations on upstream side are followed by the downstream side.
        No external energy required

      • Operating features of direct acting pressure reducing valves

        Downstream pressure changes are detected in the detection chamber, and the degree of opening of the valve is directly adjusted to maintain the set pressure.

      • Compact and cost effective design

        Can be installed in tight spaces thanks to its compact design (small/lightweight). Offers reliable operation, energy saving, and productivity improvement.

      • Superb durability

        Control bellows with moren than ... operating cycles offers outstanding durability. Protected by integrated strainer.

      • Easy handling

        Pressure can easily adjusted by the topside handle.

      Typical applications

      Perfect for small to medium steam flows as present in laundries, F&B equipment, sterilizers and similar equipment. 

      Dimensions/Weight

      RE1_124_Rc.png

       

      Size Dimensions (mm) Dimensions (in) Weight
      L H1 H2 W L H1 H2 W (kg) (lb)
      1/2” 80 137 46 65 3.2 5.4 1.8 2.6 1,4 3.1
      3/4” 90 3.5 1,6 3.5
      1” 105 144 58 4.1 5.7 2.3 1,9 4.2
      Model Connection

      Max.

      operating

       

      pressure (PMO)

      operating

      pressure range

      Control

      pressure range

      Values

      Max. pressure

      reduction ratio

      Max. operating

      temperature

      (TMO)

      Body

      material

      Type Size (MPa) (psig)

      Primary side

      pressure

      (MPa)

      Primary side

      pressure

      (psig)

      Secondary side

      pressure

      (MPa)

      Secondary side

      pressure

      (psig)

      Cv kvs (℃) (℉)
      RE1

      Screwed

      Rc,NPT

      1/2” 1,6 230 0,2 - 1,6 29 - 230 0,05 - 1,0 7.3 - 145  1,2   1,0   10:1 204 399

      Brass

      C3771

      3/4” 1,9 1,6
      1” 3,2 2,8
      RE1-2 1/2” 1,0 145 0,2 - 1,0 29 - 145 0,02 - 0,2 2.9 - 29 1,9 1,6
      3/4” 1,9 1,6
      1” 2,1   1,8   
      RE1-4 1/2” 1,0 145 0,2 - 1,0 29 - 145 0,05 - 0,4 7.3 - 58 1,2 1,0
      3/4” 1,9 1,6
      1” 3,2 2,8
      ● Recommended accessories: Y strainer / YM1  x1
      ● Offset: RE1: 0.15MPa (21.8psig) or lower, RE1-2: 0.05MPa (7.3psig) or lower, RE1-4: 0,07MPa (10.2psig) or lower
      ● Minimum differential pressure: 20% of the primary side
      ● Lockup pressure: 0,03MPa (4.4psig) or lower
      RE1
      RE1_MPa.png

      ● How to use this chart

      1. Find the point at which the upstream pressure and desired downstream pressure horizontal line intersect.

      2. Trace a vertical line from the point where they intersect, and select for the smallest-nominal size where the required steam flow rate met.

      *for downstream pressures from 0,4MPa (58psig) (4kgf/cm2・g) to 0,2MPa (29psig) (2kgf/cm2・g) or lower, use RE1-4 model.

        for downstream pressures from 0,2MPa (29psig) (2kgf/cm2・g) or lower with high flow rate, RE1-2 is recommended.

       
       

      RE1-2
      RE1-2_MPa.png

      RE1-4

      RE1-4_MPa_f.png

       

      RE1

      RE1_psig.png

      ● How to use this chart

      1. Find the point at which the upstream pressure and desired downstream pressure horizontal line intersect.

      2. Trace a vertical line from the point where they intersect, and select for the smallest-nominal size where the required steam flow rate meet.

      *for downstream pressures from 0,4MPa (58psig) (4kgf/cm2・g) to 0,2MPa (29psig) (2kgf/cm2・g) or lower, use RE1-4 model.

        for downstream pressures from 0,2MPa (29psig) (2kgf/cm2・g) or lower with high flow rate, RE1-2 is recommended.

       


      RE1-2

      RE1-2_psig.png

       

      RE1-4

      RE1-4_psig_f.png

       

      * Membership registration is required to download the documents.

      Contact