Steam/Condensate Manifold

Manifold Series Steam/Condensate Manifold
MM_P&FMM

Features/ Applications
Features
Compact design
Reduce the installation space and organize the system.
Easy handling
Installation, maintenance and replacement is simple that lead to easy inspection and lower labour cost. In combination with UNC connector, steam traps with two-bolts connection can be installed and replaced without disassembling the manifold (package) unit.
Pressure Equipment Directive (PED) Certified
Typical applications
Suitable for steam distribution and condensate collection that simplifies your steam management.
Specifications
Forged Steel
Model |
Integrated |
Max. |
Max. |
Body |
Connection |
Number of |
Connection |
Min. |
Hydrotest |
Kv Values |
Approx. |
Body material |
MM04P |
Piston Valve |
5.17MPa |
425℃ |
1-1/2”, |
NPT, SW |
4 |
1/2”, 3/4” |
-29℃ |
7.75MPa |
2.0 |
10 |
Forged steel A105 |
MM08P |
8 |
20 |
||||||||||
MM12P |
12 |
30 |
*PMO ASME 300, SW, NPT 4.15MPa
*TMO ASME 300, SW, NPT 425℃ @ 2.8MPa
(*Compact Manifold Packages are restricted by attached valves and traps.)
Fabricated Steel
Model |
Integrated |
Max. Allowable |
Max. Allowable |
Body Inlet/ |
Connection Type |
Number of |
Connection |
Min. Allowable |
Hydrotest |
Approx. |
Body material |
FMM04 |
- |
4.26MPa |
425℃ |
1/2" - 2" |
NPT, SW |
4 |
1/2”, 3/4” |
-29℃ |
6.39MPa |
11 |
Fabricated steel A106-B |
FMM06 |
6 |
15 |
|||||||||
FMM08 |
8 |
18 |
|||||||||
FMM10 |
10 |
23 |
|||||||||
FMM12 |
12 |
26 |
*PMO ASME 300, SW, NPT 4.15MPa
*TMO ASME 300, SW, NPT 240℃ @ 2.7MPa
(*Fabricated Manifold Packages conform to client’ s spec. and are restricted by attached valves and traps.)
Package Examples
Forged Steel
Fabricated Steel
●Recommendation
・Steam Traps with Two-Bolt Connection | MIYAWAKI Inc. (miyawaki-inc.com)
・Two-Bolt Connectors | MIYAWAKI Inc. (miyawaki-inc.com)
Options
■Mounting Kit
For ease of installation and insulation, an optional mounting kit is available which will provide a 2” stand-off from any adjacent structure.
The kit consists of a threaded studs, spacers and nuts, designed to match the M12 mounting holes on the back of the manifold.
The following sets are available:
4 way manifolds: Single set with 2 studs, nuts and spacers
8 way manifolds: Single set with 3 studs, nuts and spacers
12 way manifolds: Single set with 4 studs, nuts and spacers
■Structural Steelwork (Stand)
Customized structural steelwork (stand) is available to mount the manifold.
■Insulating Jacket
Customized insulating jackets are available to protect personnel from burn risks and to minimize radiated heat losses.
■Immersion Tube / Siphon Tube
Immersion Tube / Siphon Tube for condensate manifold is available to meet the requirement.
Download
* Membership registration is required to download the documents.
Features
Compact design
Reduce the installation space and organize the system.
Easy handling
Installation, maintenance and replacement is simple that lead to easy inspection and lower labour cost. In combination with UNC connector, steam traps with two-bolts connection can be installed and replaced without disassembling the manifold (package) unit.
Pressure Equipment Directive (PED) Certified
Typical applications
Suitable for steam distribution and condensate collection that simplifies your steam management.
Forged Steel
Model |
Integrated |
Max. |
Max. |
Body |
Connection |
Number of |
Connection |
Min. |
Hydrotest |
Kv Values |
Approx. |
Body material |
MM04P |
Piston Valve |
5.17MPa |
425℃ |
1-1/2”, |
NPT, SW |
4 |
1/2”, 3/4” |
-29℃ |
7.75MPa |
2.0 |
10 |
Forged steel A105 |
MM08P |
8 |
20 |
||||||||||
MM12P |
12 |
30 |
*PMO ASME 300, SW, NPT 4.15MPa
*TMO ASME 300, SW, NPT 425℃ @ 2.8MPa
(*Compact Manifold Packages are restricted by attached valves and traps.)
Fabricated Steel
Model |
Integrated |
Max. Allowable |
Max. Allowable |
Body Inlet/ |
Connection Type |
Number of |
Connection |
Min. Allowable |
Hydrotest |
Approx. |
Body material |
FMM04 |
- |
4.26MPa |
425℃ |
1/2" - 2" |
NPT, SW |
4 |
1/2”, 3/4” |
-29℃ |
6.39MPa |
11 |
Fabricated steel A106-B |
FMM06 |
6 |
15 |
|||||||||
FMM08 |
8 |
18 |
|||||||||
FMM10 |
10 |
23 |
|||||||||
FMM12 |
12 |
26 |
*PMO ASME 300, SW, NPT 4.15MPa
*TMO ASME 300, SW, NPT 240℃ @ 2.7MPa
(*Fabricated Manifold Packages conform to client’ s spec. and are restricted by attached valves and traps.)
Forged Steel
Fabricated Steel
●Recommendation
・Steam Traps with Two-Bolt Connection | MIYAWAKI Inc. (miyawaki-inc.com)
・Two-Bolt Connectors | MIYAWAKI Inc. (miyawaki-inc.com)
■Mounting Kit
For ease of installation and insulation, an optional mounting kit is available which will provide a 2” stand-off from any adjacent structure.
The kit consists of a threaded studs, spacers and nuts, designed to match the M12 mounting holes on the back of the manifold.
The following sets are available:
4 way manifolds: Single set with 2 studs, nuts and spacers
8 way manifolds: Single set with 3 studs, nuts and spacers
12 way manifolds: Single set with 4 studs, nuts and spacers
■Structural Steelwork (Stand)
Customized structural steelwork (stand) is available to mount the manifold.
■Insulating Jacket
Customized insulating jackets are available to protect personnel from burn risks and to minimize radiated heat losses.
■Immersion Tube / Siphon Tube
Immersion Tube / Siphon Tube for condensate manifold is available to meet the requirement.