Steam Fired Instantaneous Water Heater | One-Way Method

Hot Water Supply System Steam Fired Instantaneous Water Heater | One-Way Method LMG1 | Electrical safety shutoff system

Hot Water Supply System Steam Fired Instantaneous Water Heater | One-Way Method

LMG1 | Electrical safety shutoff system

      Safety additional device for LM15

      Hot Water Supply System Steam Fired Instantaneous Water Heater | One-Way Method LMG1 | Electrical safety shutoff system

      Features/Applications

      Features

      • Product Overview

        This is a system product that detects hot water supplied from the LM15 and opens an electromagnetic valve for steam (product on the market), and closes this valve when no hot water is being supplied.

      • Safety-focused design

        As well as reducing the load on the body of the water heater, it also prevents the backflow of hot water in the event of a fault in the water heater. It detects when the supply of hot water is halted and automatically shuts off the supply of steam.

      • Passed the test of effect to water quality that meet JIS

      Typical applications

      Mitigation of abnormal temperature increase and prevention of hot water backflow to cold water lines in the event of a fault in an internal component in the water heater.

      Dimensions

      Dimensions/Weight

      Control box
      LMG1_BOX.png
      Dimensions (mm) Dimensions (in) Weight
      W H D W H D (kg) (lb)
      125 75 60 4.9 3.0 2.4 0,7 1.5

       

      Flow switch
      LMG1_swith.png
       
      Dimensions (mm) Dimensions (in) Weight
      W D W D (kg) (lb)
      185 26 7.3 1.0 0,35 0.8
       

      Specifications

      Model Voltage rating

      Voltage fluctuation

      tolerance range

      Electromagnetic valve

      drive voltage

      Control input
      LMG1

      AC100/200V (50/60Hz)

      shared

      85 - 110%

      of voltage rating

      As per voltage rating
       

      AC100V 1Amax , AC200V 0.5Amax

      Flow switch
       
       
      Control

      Environmental operating

      temperature

      Environmental operating

      humidity

      Waterproof /

      dustproof

      Flow switch

      material

      When control

      input is ON
       

      Electromagnetic valve

      output ON

      -10℃~55℃ 14℉~131℉ 45~85%RH IP65 equivalent

      Body: SUS316 
       

      Socket: SUS304

      (must be no frost

      or condensation)

       
       
      Flow switch installing direction Flow switch connection

      Included cable

      Unrestricted
      (Recommended:

      Vertical downward)

      Inlet-side R1/2 ,

      outlet side Rc1/2 

      2m each for power supply,

      output, and input
      Flow switch 60cm (23.6in)

      (with waterproof connector)

      78.74in each for power supply,

      output, and inpu
      Flow switch 23.6in

      (with waterproof connector)

      Face-to-face:

      185mm

      Face-to-face:

      7.3in

      ● Electromagnetic valve required (available separately)
      ● Electromagnetic valves for steam
      When selecting an electromagnetic valve, please choose a product that conforms to the following specifications.

      For use with: Steam Max. operating pressure: 0,3MPa (43.5psig)or more Max. operating temperature: 143℃ (289℉) or more
      Cv value: 2.0 or more Voltage rating: 100VA or less Operation: On when power is on

       

       

      Installation Examples

      LM15-Ⅳ_配管例.png

      Related Products Models for reference
       Steam traps  DV1-10L
       Separator   H3  H5


      ●Precautions
      *If the way you intend to use the product involves physical contact with hot water, please be sure to separately install a thermostatic mixing valve (available on the market) in order to prevent scalding.
      *Do not use for shower systems.
      *It is not recommended that water supplied using this product be directly used for drinking water.
      *Do not use with vinyl chloride pipes or lining pipes
      *Ensure that the pressure differential between the steam supply pressure and the condensate discharge part is at least 0,03MPa (4.4psig). If back pressure is applied to the condensate discharge pipe, the maximum hot water supply rate drops.
      *If the water supplied to a hot water device contains much silica or calcium, this may cause accelerated deterioration in the performance of the main components.
      *Before use, be sure to perform an inspection in accordance with the procedure in the “Using Water Heaters Safely” document included with this product.

      Related Products

      Related Products

      Diaphragm steam trap
      DV1-10L

      thumb_dv1.jpg

       

      Pressure reducing valve for steam
      REC1

      detail_rec1.jpg

       

       Hose hanger

      All stainless steel and wall-mounted

       

      ホースハンガー.png

       

      Hose reel set for cleaning

      Max. usage temperature: 100℃ (212℉)

      Available hose length:

      5m(196.9 in), 10m (393.7 in), 15m (590.6 in)

       

      ホースリールセット.png

      Acrylic Termometer
      PU60N

      Measurement range :0-150℃ (32 - 323℉)

      External diameter     :63mm (2.5 in) 

      Screwed:R3/8

      Temperature sensor length  :40mm (1.6 in)

      PU60N.png

       

      Download

      * Membership registration is required to download the documents.

      Features

      • Product Overview

        This is a system product that detects hot water supplied from the LM15 and opens an electromagnetic valve for steam (product on the market), and closes this valve when no hot water is being supplied.

      • Safety-focused design

        As well as reducing the load on the body of the water heater, it also prevents the backflow of hot water in the event of a fault in the water heater. It detects when the supply of hot water is halted and automatically shuts off the supply of steam.

      • Passed the test of effect to water quality that meet JIS

      Typical applications

      Mitigation of abnormal temperature increase and prevention of hot water backflow to cold water lines in the event of a fault in an internal component in the water heater.

      Dimensions/Weight

      Control box
      LMG1_BOX.png
      Dimensions (mm) Dimensions (in) Weight
      W H D W H D (kg) (lb)
      125 75 60 4.9 3.0 2.4 0,7 1.5

       

      Flow switch
      LMG1_swith.png
       
      Dimensions (mm) Dimensions (in) Weight
      W D W D (kg) (lb)
      185 26 7.3 1.0 0,35 0.8
       
      Model Voltage rating

      Voltage fluctuation

      tolerance range

      Electromagnetic valve

      drive voltage

      Control input
      LMG1

      AC100/200V (50/60Hz)

      shared

      85 - 110%

      of voltage rating

      As per voltage rating
       

      AC100V 1Amax , AC200V 0.5Amax

      Flow switch
       
       
      Control

      Environmental operating

      temperature

      Environmental operating

      humidity

      Waterproof /

      dustproof

      Flow switch

      material

      When control

      input is ON
       

      Electromagnetic valve

      output ON

      -10℃~55℃ 14℉~131℉ 45~85%RH IP65 equivalent

      Body: SUS316 
       

      Socket: SUS304

      (must be no frost

      or condensation)

       
       
      Flow switch installing direction Flow switch connection

      Included cable

      Unrestricted
      (Recommended:

      Vertical downward)

      Inlet-side R1/2 ,

      outlet side Rc1/2 

      2m each for power supply,

      output, and input
      Flow switch 60cm (23.6in)

      (with waterproof connector)

      78.74in each for power supply,

      output, and inpu
      Flow switch 23.6in

      (with waterproof connector)

      Face-to-face:

      185mm

      Face-to-face:

      7.3in

      ● Electromagnetic valve required (available separately)
      ● Electromagnetic valves for steam
      When selecting an electromagnetic valve, please choose a product that conforms to the following specifications.

      For use with: Steam Max. operating pressure: 0,3MPa (43.5psig)or more Max. operating temperature: 143℃ (289℉) or more
      Cv value: 2.0 or more Voltage rating: 100VA or less Operation: On when power is on

       

       
      LM15-Ⅳ_配管例.png

      Related Products Models for reference
       Steam traps  DV1-10L
       Separator   H3  H5


      ●Precautions
      *If the way you intend to use the product involves physical contact with hot water, please be sure to separately install a thermostatic mixing valve (available on the market) in order to prevent scalding.
      *Do not use for shower systems.
      *It is not recommended that water supplied using this product be directly used for drinking water.
      *Do not use with vinyl chloride pipes or lining pipes
      *Ensure that the pressure differential between the steam supply pressure and the condensate discharge part is at least 0,03MPa (4.4psig). If back pressure is applied to the condensate discharge pipe, the maximum hot water supply rate drops.
      *If the water supplied to a hot water device contains much silica or calcium, this may cause accelerated deterioration in the performance of the main components.
      *Before use, be sure to perform an inspection in accordance with the procedure in the “Using Water Heaters Safely” document included with this product.

      Related Products

      Diaphragm steam trap
      DV1-10L

      thumb_dv1.jpg

       

      Pressure reducing valve for steam
      REC1

      detail_rec1.jpg

       

       Hose hanger

      All stainless steel and wall-mounted

       

      ホースハンガー.png

       

      Hose reel set for cleaning

      Max. usage temperature: 100℃ (212℉)

      Available hose length:

      5m(196.9 in), 10m (393.7 in), 15m (590.6 in)

       

      ホースリールセット.png

      Acrylic Termometer
      PU60N

      Measurement range :0-150℃ (32 - 323℉)

      External diameter     :63mm (2.5 in) 

      Screwed:R3/8

      Temperature sensor length  :40mm (1.6 in)

      PU60N.png

       

      * Membership registration is required to download the documents.

      Contact