Condensate Recovery Devices

Pumping Traps

Condensate Recovery Devices Pumping Traps GLP71-A

Condensate Recovery Devices Pumping Traps

GLP71-A

      Stainless steel available / Can be used in explosion prevention areas

      Condensate Recovery Devices Pumping Traps GLP71-A

      Features/Applications

      Features

      • Energy saving

        Pumping Traps are able to pressure feed low-pressure condensate to high-pressure condensate recovery lines in higher or remote locations. The incorporation of this product enables the previously unused heat energy of condensate to be recovered and efficiently utilized, thus bringing significant benefits in terms of energy saving.

      • Electricity not required

        Pushes condensate out using the pressure of the motive medium*, therefore can easily be installed in ex-proof areas.
        No need for additional power grid for remote installations.
        *As well as steam, the motive medium can be compressed air, nitrogen gas, or other such gases.

      • Low filling head

        The MIYAWAKI pumping traps have a very low filing head, providing good capacity without the need of higher collectors.

      Typical applications

       

      ● Recovery of low-pressure condensate (in combination with collectors)
      ● Support the discharge of condensate from heat exchangers operating close to or below 0 barg

      ● Stall elimination

      *Stall is a phenomenon where the steam trap does not work due to a drop in pressure on the device’s primary side and condensate builds up inside the device. Not only does this prevents the discharge of condensate, it also leads to an increased possibility of water hammer or heat exchanger corrosion occurring.

      Dimensions/Weight

      Dimensions/Weight

      GLP71_dimensions

      Dimensions (mm)

      Maintenance space (mm)

      Weight

      Weight during operation

      H H1 H2 D1 D2 D3 W W1 E

      (kg)

      (kg)

       

      656

       

       

      440

       

       

      230

       

       

      630

       

       

      615

       

       

      316

       

      457

      50

       

      550 or more

       

      150

      Max. 200

      Dimensions (in)

      Maintenance space (in)

      Weight

      Weight during operation

      H H1 H2 D1 D2 D3 W W1 E (lb) (lb)

       

      25.8

       

       

      17.3

       

       

      9.1

       

       

      24.8

       

       

      24.2

       

       

      12.4

       

      18.0

      2.0

       

      21.7 or more

       

      331

      Max. 441

      ●The body of the product can also be manufactured using stainless steel.

       

       

      Also available is the GLP71-PU package unit model that simplifies attachment and installation.
      This compact package includes the requisite piping for pumping trap operation.

      GLP71_Package Unit

      Specifications

      Model Connection

      Max. operating

      pressure

      Max. operating

      temperature

      Motive medium

      Body

      material

      Size

      PMO(MPa)

      PMO (psig)

      TMO(℃)

      TMO(℉)

      Condensate

      inlet

      Condensate

      outlet

      Motive

      medium

      Inlet

      Exhaust

      GLP71-A

       

      3"

      (Flanged*1)

       

       

      2”

      (Flanged*1)

       

       

      1/2”

      (Screwed)

       

       

      1”

      (Screwed)

       

      1,05

      152.29

      185

      365

      Steam/

      Compressed air/

      Nitrogen gas

      Carbon

      steel

      *1 Can potentially meet these flange standards: JIS10KFF ASME/JPI 150lb

      ●Maximum allowable pressure (PMA): 1,6MPa (232psig)
      ●Maximum allowable temperature (TMA): 220℃ (428℉)

       

      ●This product is sold in a set that contains the following accessories.

      Inlet-side check valve* 3”  x1
      Inlet-side gasket 3”  x2
      Inlet-side flange 3”  x1
      Inlet-side bolt nuts 8 sets (4 sets for ASME/JPI150lb)
      Outlet-side check valve* 2”     x1
      Outlet-side gasket 2”     x2
      Outlet-side flange 2”     x1
      Outlet-side bolt nuts 4 sets

      *Please be sure to use standard accessories for the inlet-side and outlet-side check valves. 

       

      Options 

       

      Liquid level gauge
      ーChecking the amount of the flow capacityー
      Cycle counter
      ーChecking the number of operatingー
      the picture of Liquid Level Gauge

      the picture of cycle counter

       

      *Conditions
      ①Indoor
      ②Non-explosion-proof areas
      ③Open areas
      ④Back pressure: 0.04MPa or more and 0.8625MPa or less

       

       

       

       

      *It can be installed only when pumping traps installation.

       

       

      Flow Capacity Chart

      Motive medium: Saturated steam
      Fluid: Condensate (Temp.85℃)
      Filling Head: 770mm

        GLP71_Flow Capacity Chart For Steam

       

       

      Motive medium: Compressed air
      Fluid: Condensate (Temp.20℃)
      Filling Head: 770mm

        GLP71_Flow Capacity Chart For Air
       

       
       
      Steam and Air consumption chart for GLP71
       
      GLP71_Steam And Air Consumption Chart
       
      Equivalent consumption of air at 20°C (68°F) under atmospheric pressure
       

       
      Filling Head FH-factors
      mm in
      150 5.9 0,66
      270 10.6 0,75
      370 14.5 0,82
      570 22.4 0,92
      770 30.3 1,00
      970 38.2 1,01
      1270 50.0 1,03
      Capacity for other fillimg heads:
      To get the capacity for other filling heads multiply
      the capacity of this chart by the "FH-factors".

      Installation Examples

      Open system

      GLP71_OpenSystem

       

      Closed system

      GLP71_ClosedSystem

       

      ■Related Products Models for reference
      Y strainer             YM1
      Check valve   CVC3
      Air vent                AT9N  AW2
      Steam trap       DV1

       

      Download

      * Membership registration is required to download the documents.

      Features

      • Energy saving

        Pumping Traps are able to pressure feed low-pressure condensate to high-pressure condensate recovery lines in higher or remote locations. The incorporation of this product enables the previously unused heat energy of condensate to be recovered and efficiently utilized, thus bringing significant benefits in terms of energy saving.

      • Electricity not required

        Pushes condensate out using the pressure of the motive medium*, therefore can easily be installed in ex-proof areas.
        No need for additional power grid for remote installations.
        *As well as steam, the motive medium can be compressed air, nitrogen gas, or other such gases.

      • Low filling head

        The MIYAWAKI pumping traps have a very low filing head, providing good capacity without the need of higher collectors.

      Typical applications

       

      ● Recovery of low-pressure condensate (in combination with collectors)
      ● Support the discharge of condensate from heat exchangers operating close to or below 0 barg

      ● Stall elimination

      *Stall is a phenomenon where the steam trap does not work due to a drop in pressure on the device’s primary side and condensate builds up inside the device. Not only does this prevents the discharge of condensate, it also leads to an increased possibility of water hammer or heat exchanger corrosion occurring.

      Dimensions/Weight

      GLP71_dimensions

      Dimensions (mm)

      Maintenance space (mm)

      Weight

      Weight during operation

      H H1 H2 D1 D2 D3 W W1 E

      (kg)

      (kg)

       

      656

       

       

      440

       

       

      230

       

       

      630

       

       

      615

       

       

      316

       

      457

      50

       

      550 or more

       

      150

      Max. 200

      Dimensions (in)

      Maintenance space (in)

      Weight

      Weight during operation

      H H1 H2 D1 D2 D3 W W1 E (lb) (lb)

       

      25.8

       

       

      17.3

       

       

      9.1

       

       

      24.8

       

       

      24.2

       

       

      12.4

       

      18.0

      2.0

       

      21.7 or more

       

      331

      Max. 441

      ●The body of the product can also be manufactured using stainless steel.

       

       

      Also available is the GLP71-PU package unit model that simplifies attachment and installation.
      This compact package includes the requisite piping for pumping trap operation.

      GLP71_Package Unit
      Model Connection

      Max. operating

      pressure

      Max. operating

      temperature

      Motive medium

      Body

      material

      Size

      PMO(MPa)

      PMO (psig)

      TMO(℃)

      TMO(℉)

      Condensate

      inlet

      Condensate

      outlet

      Motive

      medium

      Inlet

      Exhaust

      GLP71-A

       

      3"

      (Flanged*1)

       

       

      2”

      (Flanged*1)

       

       

      1/2”

      (Screwed)

       

       

      1”

      (Screwed)

       

      1,05

      152.29

      185

      365

      Steam/

      Compressed air/

      Nitrogen gas

      Carbon

      steel

      *1 Can potentially meet these flange standards: JIS10KFF ASME/JPI 150lb

      ●Maximum allowable pressure (PMA): 1,6MPa (232psig)
      ●Maximum allowable temperature (TMA): 220℃ (428℉)

       

      ●This product is sold in a set that contains the following accessories.

      Inlet-side check valve* 3”  x1
      Inlet-side gasket 3”  x2
      Inlet-side flange 3”  x1
      Inlet-side bolt nuts 8 sets (4 sets for ASME/JPI150lb)
      Outlet-side check valve* 2”     x1
      Outlet-side gasket 2”     x2
      Outlet-side flange 2”     x1
      Outlet-side bolt nuts 4 sets

      *Please be sure to use standard accessories for the inlet-side and outlet-side check valves. 

       

      Options 

       

      Liquid level gauge
      ーChecking the amount of the flow capacityー
      Cycle counter
      ーChecking the number of operatingー
      the picture of Liquid Level Gauge

      the picture of cycle counter

       

      *Conditions
      ①Indoor
      ②Non-explosion-proof areas
      ③Open areas
      ④Back pressure: 0.04MPa or more and 0.8625MPa or less

       

       

       

       

      *It can be installed only when pumping traps installation.

       

       

      Motive medium: Saturated steam
      Fluid: Condensate (Temp.85℃)
      Filling Head: 770mm

        GLP71_Flow Capacity Chart For Steam

       

       

      Motive medium: Compressed air
      Fluid: Condensate (Temp.20℃)
      Filling Head: 770mm

        GLP71_Flow Capacity Chart For Air
       

       
       
      Steam and Air consumption chart for GLP71
       
      GLP71_Steam And Air Consumption Chart
       
      Equivalent consumption of air at 20°C (68°F) under atmospheric pressure
       

       
      Filling Head FH-factors
      mm in
      150 5.9 0,66
      270 10.6 0,75
      370 14.5 0,82
      570 22.4 0,92
      770 30.3 1,00
      970 38.2 1,01
      1270 50.0 1,03
      Capacity for other fillimg heads:
      To get the capacity for other filling heads multiply
      the capacity of this chart by the "FH-factors".

      Open system

      GLP71_OpenSystem

       

      Closed system

      GLP71_ClosedSystem

       

      ■Related Products Models for reference
      Y strainer             YM1
      Check valve   CVC3
      Air vent                AT9N  AW2
      Steam trap       DV1

       

      * Membership registration is required to download the documents.