Pumping Traps
Condensate Recovery Devices Pumping Traps
GLP71-A
Stainless steel available / Can be used in explosion prevention areas
Features/Applications
Features
Energy saving
Pumping Traps are able to pressure feed low-pressure condensate to high-pressure condensate recovery lines in higher or remote locations. The incorporation of this product enables the previously unused heat energy of condensate to be recovered and efficiently utilized, thus bringing significant benefits in terms of energy saving.
Electricity not required
Pushes condensate out using the pressure of the motive medium*, therefore can easily be installed in ex-proof areas.
No need for additional power grid for remote installations.
*As well as steam, the motive medium can be compressed air, nitrogen gas, or other such gases.
Low filling head
The MIYAWAKI pumping traps have a very low filing head, providing good capacity without the need of higher collectors.
Typical applications
● Recovery of low-pressure condensate (in combination with collectors)
● Support the discharge of condensate from heat exchangers operating close to or below 0 barg
● Stall elimination
*Stall is a phenomenon where the steam trap does not work due to a drop in pressure on the device’s primary side and condensate builds up inside the device. Not only does this prevents the discharge of condensate, it also leads to an increased possibility of water hammer or heat exchanger corrosion occurring.
Dimensions/Weight
Dimensions/Weight
Dimensions (mm) |
Maintenance space (mm) |
Weight |
Weight during operation |
|||||||||||
H | H1 | H2 | D1 | D2 | D3 | W | W1 | E |
(kg) |
(kg) |
||||
656
|
440
|
230
|
630
|
615
|
316
|
457 |
50 |
550 or more
|
150 |
Max. 200 |
||||
Dimensions (in) |
Maintenance space (in) |
Weight |
Weight during operation |
|||||||||||
H | H1 | H2 | D1 | D2 | D3 | W | W1 | E | (lb) | (lb) | ||||
25.8
|
17.3
|
9.1
|
24.8
|
24.2
|
12.4
|
18.0 |
2.0 |
21.7 or more
|
331 |
Max. 441 |
●The body of the product can also be manufactured using stainless steel.
Also available is the GLP71-PU package unit model that simplifies attachment and installation.
This compact package includes the requisite piping for pumping trap operation.
Specifications
Model | Connection |
Max. operating pressure |
Max. operating temperature |
Motive medium |
Body material |
|||||
Size |
PMO(MPa) |
PMO (psig) |
TMO(℃) |
TMO(℉) |
||||||
Condensate inlet |
Condensate outlet |
Motive medium Inlet |
Exhaust |
|||||||
GLP71-A |
3" (Flanged*1)
|
2” (Flanged*1)
|
1/2” (Screwed)
|
1” (Screwed)
|
1,05 |
152.29 |
185 |
365 |
Steam/ Compressed air/ Nitrogen gas |
Carbon steel |
*1 Can potentially meet these flange standards: JIS10KFF ASME/JPI 150lb
●Maximum allowable pressure (PMA): 1,6MPa (232psig)
●Maximum allowable temperature (TMA): 220℃ (428℉)
●This product is sold in a set that contains the following accessories.
Inlet-side check valve* | 3” x1 |
Inlet-side gasket | 3” x2 |
Inlet-side flange | 3” x1 |
Inlet-side bolt nuts | 8 sets (4 sets for ASME/JPI150lb) |
Outlet-side check valve* | 2” x1 |
Outlet-side gasket | 2” x2 |
Outlet-side flange | 2” x1 |
Outlet-side bolt nuts | 4 sets |
*Please be sure to use standard accessories for the inlet-side and outlet-side check valves.
Options
・Liquid level gauge ーChecking the amount of the flow capacityー |
・Cycle counter ーChecking the number of operatingー |
*Conditions
|
|
*It can be installed only when pumping traps installation. |
|
Flow Capacity Chart
Motive medium: Saturated steam
Fluid: Condensate (Temp.85℃)
Filling Head: 770mm
Motive medium: Compressed air
Fluid: Condensate (Temp.20℃)
Filling Head: 770mm
Filling Head | FH-factors | |
mm | in | |
150 | 5.9 | 0,66 |
270 | 10.6 | 0,75 |
370 | 14.5 | 0,82 |
570 | 22.4 | 0,92 |
770 | 30.3 | 1,00 |
970 | 38.2 | 1,01 |
1270 | 50.0 | 1,03 |
the capacity of this chart by the "FH-factors".
Installation Examples
Open system
Closed system
■Related Products Models for reference
Y strainer YM1
Check valve CVC3
Air vent AT9N AW2
Steam trap DV1
Download
* Membership registration is required to download the documents.
Features
Energy saving
Pumping Traps are able to pressure feed low-pressure condensate to high-pressure condensate recovery lines in higher or remote locations. The incorporation of this product enables the previously unused heat energy of condensate to be recovered and efficiently utilized, thus bringing significant benefits in terms of energy saving.
Electricity not required
Pushes condensate out using the pressure of the motive medium*, therefore can easily be installed in ex-proof areas.
No need for additional power grid for remote installations.
*As well as steam, the motive medium can be compressed air, nitrogen gas, or other such gases.
Low filling head
The MIYAWAKI pumping traps have a very low filing head, providing good capacity without the need of higher collectors.
Typical applications
● Recovery of low-pressure condensate (in combination with collectors)
● Support the discharge of condensate from heat exchangers operating close to or below 0 barg
● Stall elimination
*Stall is a phenomenon where the steam trap does not work due to a drop in pressure on the device’s primary side and condensate builds up inside the device. Not only does this prevents the discharge of condensate, it also leads to an increased possibility of water hammer or heat exchanger corrosion occurring.
Dimensions/Weight
Dimensions (mm) |
Maintenance space (mm) |
Weight |
Weight during operation |
|||||||||||
H | H1 | H2 | D1 | D2 | D3 | W | W1 | E |
(kg) |
(kg) |
||||
656
|
440
|
230
|
630
|
615
|
316
|
457 |
50 |
550 or more
|
150 |
Max. 200 |
||||
Dimensions (in) |
Maintenance space (in) |
Weight |
Weight during operation |
|||||||||||
H | H1 | H2 | D1 | D2 | D3 | W | W1 | E | (lb) | (lb) | ||||
25.8
|
17.3
|
9.1
|
24.8
|
24.2
|
12.4
|
18.0 |
2.0 |
21.7 or more
|
331 |
Max. 441 |
●The body of the product can also be manufactured using stainless steel.
Also available is the GLP71-PU package unit model that simplifies attachment and installation.
This compact package includes the requisite piping for pumping trap operation.
Model | Connection |
Max. operating pressure |
Max. operating temperature |
Motive medium |
Body material |
|||||
Size |
PMO(MPa) |
PMO (psig) |
TMO(℃) |
TMO(℉) |
||||||
Condensate inlet |
Condensate outlet |
Motive medium Inlet |
Exhaust |
|||||||
GLP71-A |
3" (Flanged*1)
|
2” (Flanged*1)
|
1/2” (Screwed)
|
1” (Screwed)
|
1,05 |
152.29 |
185 |
365 |
Steam/ Compressed air/ Nitrogen gas |
Carbon steel |
*1 Can potentially meet these flange standards: JIS10KFF ASME/JPI 150lb
●Maximum allowable pressure (PMA): 1,6MPa (232psig)
●Maximum allowable temperature (TMA): 220℃ (428℉)
●This product is sold in a set that contains the following accessories.
Inlet-side check valve* | 3” x1 |
Inlet-side gasket | 3” x2 |
Inlet-side flange | 3” x1 |
Inlet-side bolt nuts | 8 sets (4 sets for ASME/JPI150lb) |
Outlet-side check valve* | 2” x1 |
Outlet-side gasket | 2” x2 |
Outlet-side flange | 2” x1 |
Outlet-side bolt nuts | 4 sets |
*Please be sure to use standard accessories for the inlet-side and outlet-side check valves.
Options
・Liquid level gauge ーChecking the amount of the flow capacityー |
・Cycle counter ーChecking the number of operatingー |
*Conditions
|
|
*It can be installed only when pumping traps installation. |
|
Motive medium: Saturated steam
Fluid: Condensate (Temp.85℃)
Filling Head: 770mm
Motive medium: Compressed air
Fluid: Condensate (Temp.20℃)
Filling Head: 770mm
Filling Head | FH-factors | |
mm | in | |
150 | 5.9 | 0,66 |
270 | 10.6 | 0,75 |
370 | 14.5 | 0,82 |
570 | 22.4 | 0,92 |
770 | 30.3 | 1,00 |
970 | 38.2 | 1,01 |
1270 | 50.0 | 1,03 |
the capacity of this chart by the "FH-factors".
* Membership registration is required to download the documents.